Pass Through Sterilizer
Systec H-Series 2D
Intran is the exclusive agent for Systec’s Sterilizer systems for Malaysia region.
With a consolidated product offering, Syetec offers quality, innovation and range for all your sterilization needs
The Systec H-Series 2D double-door/pass-through autoclaves of the performance category HX can be used for all laboratory applications, even for sophisticated sterilization processes and are available in 13 different sizes with 90 to 1580 liters chamber volume. All additional optional accessories can be fitted to obtain validatable processes. For use under the most stringent clean room and safety conditions: For biological safety laboratories, e.g. fitting as a sterilization and pass-through lock for protecting the external environment, for clean rooms in laboratories and production facilities as a sterilization and pass-through lock separating sterile and non-sterile areas.

DOUBLE-DOOR/PASS-THROUGH AUTOCLAVES SYSTEC H-SERIES 2D

SYSTEC HX - The Expert
- For all laboratory applications even for sophisticated state-of-the-art sterilization processes. With all possibilities to add additional options for process optimization to enable validatable sterilization to be carried out.


Salient Features across the range
State-of-the-art engineering
Systec autoclaves are state-of-the-art, both in their mechanical and electrical components; ensuring a new quality of laboratory sterilization processes. The enhanced components enable the lab to meet appropriate requirements for today and the future.Available with two chamber diameter
Available with two chamber diameter: 740 mm and 1000 mm. 1000 mm diameter chamber provides the usable chamber dimension of a 6 x 6 square chamber autoclave.All-round quality
The pressure vessel is made of corrosion-resistant stainless steel 1.4571 (V4A) AISI 316 Ti and is thus easy to clean. An approved safety valve for excess pressure is included. The autoclave support framework and housing are also made of stainless steel. The highly efficient, high-quality Hanno-Tect insulation material releases no particles; Systec autoclaves can thus be used under clean-room conditions.Dual sensors as standard
Temperature and pressure are controlled via an electronic pressure sensor, as well as a flexible temperature sensor in the chamber or in a reference vessel (with liquids). Systec HX autoclaves also have an additional temperature sensor in the floor drain.Triple safety aspects:
One door only can be opened at a time. If one door is open, the other is automatically locker.
If the autoclave is switched off or of no current is available (e.g. power failure), booth doors remains locked.
If the door at the non-sterile side is opened, a sterilization program hast to be performed before the door at the sterile side can be opened.